Using v/f control mode, Adjusting torque according to application – IDEX Health & Science VS-606V7 Series User Manual

Page 40

Advertising
background image

40

Using V/f Control Mode

Vector control mode is preset at the factory.

Control mode selection (n002): 0: V/f control mode (initial setting)

1: Vector control mode

Adjust motor torque by using “V/f pattern” and “full-range automatic torque boost”.

V/f pattern setting
Set V/f pattern by n011 to n017 as described below. Set each pattern when using a
special motor (high-speed motor, etc.) or when requiring special torque adjustment
of machine.

Be sure to satisfy the following
conditions for the setting of n011
to n017.
n016 < n014 < n013 < n011
If n016 = n014 is set, the set
value of n015 is disabled.

Adjusting torque according to application

Parameters

No.

Name

Unit

Setting range

Initial Setting

n011

Max. output frequency

0.1Hz

50.0 to 400.0Hz

60.0Hz

n012

Max. voltage

1V

1 to 255.0V

(0.1 to 510.0V)

230.0V

(460.0V)

n013

Max. voltage output frequency
(base frequency)

0.1Hz

0.2 to 400.0Hz

60.0Hz

n014

Mid. output frequency

0.1Hz

0.1 to 399.9Hz

1.5Hz

n015

Mid. output frequency voltage

1V

0.1 to 255.0V

(0.1 to 510.0V)

12.0V

(24.0V)

n016

Min. output frequency

0.1Hz

0.1 to 10.0Hz

1.5Hz

n017

Min. output frequency voltage

1V

1 to 50.0V

(0.1 to 100.0V)

4.3V *
(8.6V)

n016 n014 n013 n011 (frequency)

* 10.0V for 200V class 7.5/10hp (5.5/7.5kW)
20.0V for 400V class 7.5/10hp (5.5/7.5kW)
NOTE: Values with parentheses indicate 400V class.