First Functions (Parameters n001 to n049)

No.

Register

No. for

Trans-

mission

Name

Setting Range

Setting

Unit

Initial

Setting

User

Setting

Ref.

Page

001

0101H

Parameter write-in
prohibit / initialize

0 to 4, 6, 8, 9,

12, 13

1

1

39

002

0102

Control mode selection (Note
6)

0,1

1

0 (Note 1)
(Note 6)

40

003

0103

Operation reference
selection

0 to 3

1

0

47

004

0104

Frequency reference
selection

0 to 9

1

1

48

005

0105

Stopping method
selection

0, 1

1

0

71

006

0106

REV run prohibit

0, 1

1

0

50

007

0107

Operation stop enable/
disable selection

0, 1

1

0

70

008

0108

Frequency reference
selection
in local mode

0, 1

1

1 (Note 5)

48

009

0109

Setting method selection
for frequency reference

0, 1

1

0

48

010

010A

Detecting selection of
operator connecting fault

0, 1

1

0

47

011

010B

Maximum output
frequency

50.0 to

400.0Hz

0.1Hz

50.0Hz

40

012

010C

Maximum voltage

0.1 to 255.0V (0.2

to 510.0)

0.1V

200.0V (Note

2)

40

013

010D

Maximum voltage output
frequency

0.2 to 400.0Hz

0.1Hz

50.0Hz

40

014

010E

Mid. output frequency

0.1 to 399.9

0.1Hz

1.3Hz

40

015

010F

Mid. output frequency
voltage

0.1 to 255.0V

0.1V

12.0V

(Note 2)

40

016

0110

Minimum output
frequency

0.1 to 10.0Hz

0.1Hz

1.3Hz

40

017

0111

Minimum output
frequency voltage

0.1 to 50.0V

0.1V

12.0V

(Note 2)

40

018

0112

Accel / decel time setting
unit

0,1

1

0

55

019

0113

Acceleration time 1

0.00 to 6000s

Depend on

n018 setting

10.0s

55

020

0114

Deceleration time 1

0.00 to 6000s

Depend on

n018 setting

10.0s

55

021

0115

Acceleration time 2

0.00 to 6000s

Depend on

n018 setting

10.0s

55

022

0116

Deceleration time 2

0.00 to 6000s

Depend on

n018 setting

10.0s

55

023

0117

S-curve accel / decel
selection

0 to 3

1

0

56