IDEX Health & Science VS-606V7 Series User Manual

Page 163

Advertising
background image

163

127

017F

Frequency reference 16

0.00 to

400.0Hz

0.01Hz (less

than 100Hz) /
0.1Hz (100Hz

or more)

0.00Hz

51

128

0180

PID control selection

0 to 8

1

0

110

129

0181

PID feedback gain

0.00 to 10.00

0.01

1.00

113

130

0182

Proportional gain (P)

0.0 to 25.0

0.1

1.0

111

131

0183

Integral time (I)

0.0 to 360.0

0.1s

1.0

111

132

0184

Derivative time (D)

0.00 to 2.50

0.01s

0.00

111

133

0185

PID offset adjustment

-100 to 100%

1%

0%

112

134

0186

Integral (I) upper limit

-100 to 100%

1%

100%

112

135

0187

PID output primary delay
parameter time

0.0 to 10.0

0.1s

0.0

112

136

0188

PID feedback loss
detection selection

0,1,2

1

0

113

137

0189

PID feedback loss
detection level

0 to 100%

1%

0%

113

138

018A

PID feedback loss
detection time

0.0 to 25.5

0.1s

1.0

113

139

018B

Energy-saving control
selection (V/f control
mode)

0,1

1

0

105

140

018C

Energy-saving
coefficient K2

0.0 to 6550

0.1

(Note 7)

105

141

018D

Energy-saving voltage
lower limiter (at 60 Hz)

0 to 120%

1%

50%

106

142

018E

Energy-saving voltage
lower limiter (at 6 Hz)

0 to 25%

1%

12%

106

143

018F

Power average time

1 to 200

1 = 24ms

1 (24ms)

107

144

0190

Search operation voltage
limit

0 to 100%

1%

0%

107

145

0191

Search operation voltage
step (at 100%)

0.1 to 100%

0.1%

0.5%

107

146

0192

Search operation voltage
step (at 5%)

0.1 to 10.0%

0.1%

0.2%

107

149

0195

Pulse train input scaling

100 to 3300

1 (1 = 10Hz)

2500

(25kHz)

85

150

0196

Pulse monitor output
frequency selection

0,1,6,12,24,36

---

0

66

No.

Register

No. for

Trans-

mission

Name

Setting Range

Setting

Unit

Initial

Setting

User

Setting

Ref.

Page

Advertising