Function outline, N035 setting – IDEX Health & Science VS-606V7 Series User Manual

Page 125

Advertising
background image

125

Unit selection for Frequency Reference Setting/
Display

Parameter and monitor display for which selection of unit function is valid

Function Outline

The frequency reference, output frequency and the numerical data of frequency
reference parameters can be displayed in %, r/min, m/min according to the set value of
parameter n035.

n035 setting

Item

Contents

Frequency
reference
parameters

Frequency reference 1 to 8 (Parameters n024 to n031)

Jog frequency reference (Parameters n032)

Frequency reference 9 to 16 (parameters n120 to n127)

Monitor display

Frequency reference display (FREF)

Output frequency display (FOUT)

Frequency reference display (U-01)

Output frequency display (U-02)

Parameter

No.

Parameter Name

Description

Initial

Setting

035

Unit Selection for
frequency Reference
Setting / Display

0: in units of 0.01 Hz (less than 100 Hz)
0.1Hz (100 Hz and more)
1: in units of r/min (set the number of motor

poles)

40 to 3999: in any unit

0

Setting

Description

0

(Initial value)

• Setting unit: 0.01 Hz (less than 100 Hz), 0.1 Hz (100 Hz and more)
• Setting range
min{Fmax (n011) x Frequency reference lower limit (n034) to Fmax (n011) Frequency

reference upper limit (n033), 400 Hz}

1

• Setting in units of 0.1% : 100.0 % / Fmax (n011)
• Setting range
min{Frequency reference lower limit (n034) to Frequency reference upper limit (n033),

(400 Hz ÷ Fmax (n011) 100%}

2 to 39

• Setting in units of 1 r/min = 120 x Frequency reference (Hz) ÷ n035
(Set the number of motor poles for n035)
• Setting range
min{120 (Fma x (n011) Frequency reference lower limit (n034) ÷ n035~120x

Fmax(n011) x Frequency reference upper limit (n033)) n035, 400Hzx120 P, 9999r/min

• Set the display value at 100% of frequency reference (set value of Fmax (n011)) at 1 of

n035.

(Lit)