IDEX Health & Science VS-606V7 Series User Manual

Page 78

Advertising
background image

78

Communication/multi-function input terminal selection input
(setting: 18)

Operation can be changed from communication command, or from multi-function
input terminal or digital operator command.

Run command from communication and frequency reference are effective when
multi-function input terminal for this setting is “closed (register No. 0001H,
0002H).”
Run command in LOCAL/REMOTE mode and frequency reference are effective
when “Open.”

The input analog signal (0 to 10V or 4mA to 20mA) for the CN2 terminal of the
JVOP-140 digital operator can be used as an auxiliary function for the main speed
frequency reference input to the control circuit terminals (FR or RP). Refer to the

block diagram on page 111 for details of the input signal.

Multi-function input selection (n077)

Using multi-function analog input (n077, n078, n079)

NOTE

When using the signal for the CN2 terminal of the JVOP-140 digital operator’s
a multi-function analog input, never use it or the target value or the feedback
value of PID control. (PID control is disabled when n128 is set to 0.)

No.

Name

Unit

Setting

Range

Initial

Setting

n077

Multi-function

input selection

_

0 to 4

0