Motor protection, Motor overload detection – IDEX Health & Science VS-606V7 Series User Manual

Page 90

Advertising
background image

90

Motor Protection

The VS-606V7 protects against motor overload with a built-in electronic thermal
overload relay.

Motor rated current (electronic thermal reference current, n036)
Set to the rated current value shown on the motor nameplate.

Note:

Setting to 0.0A disables the motor overload protective function.

Motor overload protection selection (n037, n038).

The electronic thermal overload function monitors motor temperature, based on
inverter output current and time, to protect the motor from overheating. When
electronic thermal overload relay is enabled, an “

” error occurs, shutting OFF the

inverter output and preventing excessive overheating in the motor. When operating
with one inverter connected to one motor, an external thermal relay is not needed.
When operating several motors with one inverter, install a thermal relay on each motor.

Motor overload detection

n037 Setting

Electronic Thermal Characteristics

0

Applied to general-purpose motor

1

Applied to inverter duty motor

2

Electronic thermal overload protection not provided

Parameters

No.

Name

Unit

Setting Range

Initial Setting

n038

Protection parameter
selection

1min

1 to 60min

8min