Decreasing Motor Speed Fluctuation

As the load becomes larger, motor speed is reduced and motor slip value is increased.
The slip compensating function controls the motor speed at a parameter value even if
the load varies.

When inverter output current is equal to the motor rated current (n036), the
compensation frequency is added to the output frequency.

Related Parameters

* Differs depending on inverter capacity.

Notes: 1.

Slip compensation is not performed in the following condition:
Output frequency < minimum output frequency (n016).

2.

Slip compensation is not performed during regeneration.

3.

Slip compensation is not performed when motor rated current (n036) is
set to 0.0A.

Slip compensation (When V/f control mode n002=0)

Parameters

No.

Name

Unit

Setting Range

Initial

Setting

n036

Motor rated current

0.1A 0 to 150% of inverter rated current

*

n111

Slip compensation gain

0.1

0.0 to 2.5

0.0

n110

Motor no-load current

1%

0 to 99% (100% = Motor rated current n036)

*

n112

Slip compensation primary
delay time

0.1s

0.0 to 25.5s
When 0.0s is set, delay time becomes 2.0s.

2.0s

n106

Motor rated slip

0.1Hz 0.0 to 20Hz

*

Compensation frequency

Motor rated slip (n106)

=

Output current

Motor no-load current (n110)

Electronic thermal

reference current (n036)

Motor no-load current (n110)

---------------------------------------------------------------------------------------------------------------------------------------------------

×

Slip compensation gain (n111)

Ч