Termination resistance, Address setting – 2N Lift8 v1.6.0 User Manual

Page 105

Advertising
background image

105

2N TELEKOMUNIKACE a.s., www.2n.cz

®

Main bus

1 … Main bus power +
2 … Main bus power -
3 … Main bus audio +
4 … Main bus audio -
5 … Main bus data +
6 … Main bus data -

Termination Resistance

Figure:

Termination Resistance Off

Address Setting

Use a 10-pin rotary switch 0–9 (see the figure above) to set the I/O Module address for
a lift. Set 1–8 like the shaft number for the splitter (set 5 for lift 5, e.g.).

Warning

Maintain the connection polarity to make the

system work

2N Lift8

®

correctly.

Warning

The bus is electrically isolated from the telephone line circuits according to
the EN60950 requirements and its low voltage cannot cause any electrical
accident.

Caution

Find the 3-pin termination resistance connecting jumper between the
main bus connector and lift number switch.
Connect the jumper to the first and last device (CU, splitter or I/O
module) on the bus. Refer to the CU section for more details.
By default, the termination resistance jumper is off.

Warning

Do not set address 0 and 9 to avoid system error.

Advertising