Setting options – 2N Lift8 v1.6.0 User Manual

Page 172

Advertising
background image

172

2N TELEKOMUNIKACE a.s., www.2n.cz

®

Then enter the –cImportDatabase parameter and the file path to import the database:

C:\Program Files\2N TELEKOMUNIKACE\ 2N Lift8\Server\l8-config.exe
–cImportDatabase "C:\ProgramData\2N TELEKOMUNIKACE\ 2N
Lift8\Server\db–20130221095921–export.xml"

Now all the database tables start being exported sequentially. Every successful table
import is confirmed.

Restart the server after every successful database import using the following
command:

C:\Program Files\2N TELEKOMUNIKACE\ 2N Lift8\Server\l8-config.exe –cStartServer

Setting Options

The l8-config program provides numerous server settings; see the long list below.

General Commands

–l

writes out all the parameters.

--help or –h

displays Help.

--version or -V

writes out the program version.

-d

sets the server data directory.

Parameter Get Commands

–gListenPort

writes out the server listening port.

Caution

The path to the exported database file must always be given in inverted
commas. If no path is found, the current database will be deleted and
replaced with a new, empty one.

Note

If the database includes a high number of users and terminals, the table
import will take a few minutes.

Tip

The

parameters

are

set

as

program

parameters:

program

name<space>program parameter.

Advertising