Led indicator connection, Voltage control – 2N Lift8 v1.6.0 User Manual

Page 51

Advertising
background image

51

2N TELEKOMUNIKACE a.s., www.2n.cz

®

1.
2.

3.

Voltage control

Requirements

DC 12 to 48V voltage

Procedure

Move the CANCEL terminal two pins up into position (4).
For activation by voltage connection, leave the jumper as it is (6th pin on jumper
12) – CANCEL without jumper fitted (factory setting).
For activation by voltage disconnection, fit the jumper (6th pin on jumper 12) –
CANCEL inverted – jumper fitted.

LED Indicator Connection

The current LED technology makes it possible to achieve a relatively good light
intensity with a small current. If the lift indicators are illuminated with a sufficiently
efficient LED requiring a current of approx. 5 mA (with diode loss of about 2 V), no
power supply is needed. See the figure below for the connection.

Figure: Alternative LED Connection for Audio Unit – Cabin Universal

Warning

Ignoring the instructions above may lead to product damage.
The CANCEL function only works when the cabin

is set to the

audio unit

cabin position (default).

Caution

Remember to program delayed calling to make the CANCEL connection
work successfully.
Refer to the electronics cover for the ALARM and CANCEL configuration
scheme.

Advertising