Volume Configuration

Slightly loosen the four screws and shift the cover downwards. Now you can remove
the cover. Use the trimmer located in the bottom part of the electronics to set the
required volume level (see the figure below).

Induction Loop Connection

The regulations that apply to communicator installations may require a mandatory loop
for persons with defective hearing in the lift cabin. In that case, connect the loop to
connector (10) with any polarity. The loop including a 1m long cable can be part of
your delivery if agreed so.

Requirements

The induction loop has to be placed behind a non-metal, non-magnetic cover in
the control panel as the magnetic field of the induction loop cannot go through a
metal control panel.
The induction loop has to be labelled with an appropriate symbol (ear) placed
according to the applicable standards.

Caution

External pictograms are connected to connectors 7 and 8 on the cabin
audio unit.

The manufacturer, 2N TELEKOMUNIKACE a.s., hereby declares that the

External Pictogram Driver is in compliance with the essential

2N Lift8

®

requirements and other relevant provisions of the 1999/5/EC Directive.
The Declaration of Conformity is attached to the basic module of 2N

®

and also available at

.

Lift8

www.2n.cz

Caution

Use the trimmer to set the best acoustic properties eliminating feedback.