Bus connection, Alarm button connection, Button control – 2N Lift8 v1.6.0 User Manual

Page 49

Advertising
background image

49

2N TELEKOMUNIKACE a.s., www.2n.cz

®

1.
2.

3.

Bus Connection

Pull the terminal out of connector 1 - Audio units bus, connect the bus audio units
wires and replace the terminal to connector 1. Mind the polarity.

ALARM Button Connection

Requirements

The ALARM button design (colour, symbol, keypad surface, mechanical operation)
and location have to meet the requirements of the particular installation.

Button control

Requirements

The ALARM button has to be equipped with a make or break (NO/NC) contact
that is not connected with any other circuit.
None of the ALARM button terminals may be connected electrically with any other
electrical circuit and no voltage source other than the NO/NC contact may be
connected to them.
If one of the ALARM contacts is connected to another circuit, an appropriate
isolation strength according to the applicable standards has to be ensured
between the contacts.

Procedure

Leave the ALARM terminal in the lower position (3).
If you use a make contact, leave the jumper as it is (5th pin on jumper 12) –
ALARM without jumper fitted (factory setting).
If you use a break contact, fit the jumper (5th pin on jumper 12) – ALARM
inverted – jumper fitted.

Warning

Connection to different, e.g. higher-voltage, cables leads to damage or
destruction of the

.

audio unit

Maintain polarity while connecting the

to avoid

error.

audio unit

audio unit

Caution

The

is powered via a 2-wire bus. Disconnection of these wires

audio unit

results in the

switch-off.

audio unit

Avoid the

address duplicity.

audio unit