Rescue Process

The rescue (extrication) process is activated after the alarm call end.
The yellow LED keeps shining on the audio unit.
The service technician enters a valid password via the

voice menu

2N Lift8

®

to terminate the process.
When the rescue password is entered via the voice menu, the yellow LED goes
off on the audio unit and the 'Rescue process was terminated' is played.

Caution

Access the voice menu (during an incoming call to L8 or from the machine
room) to terminate the rescue process. Enter the administration menu (9)
and press (2) to terminate the rescue process. Enter the shaft number
(only if multiple audio units are involved in the rescue process) and enter
the rescue terminating password.

Warning

Remember to set the rescue password (parameter 992) to activate the
rescue function.
The rescue process can only be activated on a cabin audio unit configured
as the cabin (default audio unit setting).