Mounting types, Output relay connection, Wall mounting – 2N Lift8 v1.6.0 User Manual

Page 107

Advertising
background image

107

2N TELEKOMUNIKACE a.s., www.2n.cz

®

Output Relay Connection

Every I/O Module is equipped with 4 bistable relays with the maximum load of 250 V /
5 A per contact. Never exceed this limit to avoid system damage. When the relay is
closed, the respective LED signals this state. You can configure the relay function in the

application.

2N

Service Tool

®

Figure:

Example of Output Relay Connection

Mounting Types

See below for the mounting types and necessary components. Install the device on
sites not exposed to water leakage or condensation.

Wall Mounting

Use appropriate wall plugs and screws for mounting (not included in the delivery).
Hang the device using the pre-drilled holes on the device bottom.

Warning

Never exceed the voltage and current limits specified in the Technical
Parameters for the load applied to the relay contacts to avoid system
damage.

Warning

Never connect any important structural devices such as brakes, door
locks, security equipment, etc. to the relay outputs. The I/O Module is

Connect

not designed and must not be used for such installations.
only the devices that will not be damaged by unexpected relay contact
disconnection (CU remote upgrade, bus restart, etc.) such as unimportant
signalling lamps, ventilators, shaft lights, etc.).
The manufacturer shall not be held liable for damage incurred as a
result of improper installations on the relay contact.

Advertising