Delayed call

0–1000 s

0 s

Used only with connected
CANCEL input on the cabin
audio unit.

915

Max.
TRIPHONY
time

10–9999 s

7200 s

Maximum TRIPHONY period
after which TRIPHONY is
terminated automatically.

917

Hang-up time
between calls

500–9999 ms

5000 ms

For PSTN lines only.

918

Max.
telephone
line test time

1–20s

5 s

not implemented

940

Min. dialtone
period

200–2000 ms

400 ms

The tone must be longer
than a half-period of the
busy tone!

941

Min. constant
tone time

200–9999 ms

2000 ms

not implemented

942

Min. busy
tone period

100–500 ms

200 ms

These parameters control
the busy tone detection.

944

Max. tone –
gap
difference

10–400 ms

50 ms

945

Min. busy
tone period
count

2–50

5

948

Min. ringback
tone time

50–2000 ms

200 ms

not implemented

949

Min. long
space time of
ringback tone

100–5000 ms

2500 ms

not implemented

950

Max. long
space time of
ringback tone

500–9999 ms

5500 ms

not implemented

951

Min. ringing
signal time

50–2000 ms

200 ms

Incoming call detection:

The ringtone time is the
sum of sections between
which there is no long gap.
The longest gap in the
ringing period must be in
the interval between
parameters 952 and 953.

CAUTION! Parameters
951–953 (default values)
work for incoming ringing.

952

Min. long
space time of
ringing
signal

100–5000 ms

1000 ms

953

Max. long
space time of
ringing signal

500–9999 ms

6000 ms

961

Max. next
digit pressing
time

15–120 s

60 s

Counted from the transition
to a new state (NOT after
the end of announcement).

962

Min. cabin
ALARM
button
pressing time

10–9999 ms

100 ms

A low value is
recommended for
comfortable product
testing.