MDC-360C DEPOSITION CONTROLLER

PROGRAMMING AND CONTROLLER SETUP

4-44

7. Data Points/Min (30,60,120,300,600 PPM)

This parameter sets the number of run-time data point sets per minute that will be
written to the process log. The default is 600 data points/minute. During a
process, data is logged automatically up to 10 data point sets per minute. At this
rate the 27,000 data point storage can hold 45 minutes of data. To allow for
longer processes, you can change the number of data point sets stored per minute.
The following table shows the approximate storage time based on the number of
data points per minute parameter. Press the ‘Enter’ key to cycle between options.
This parameter is only visible when the data logging option is installed.

Data Points/Minute

Approx. Storage Time

(minutes)

30 900
60 450

120 225
300 90
600 45

8. Time (00:00-23:59)

This parameter sets the system time. Time is entered in 24-hour format without a
digit separator “:”. For example, to enter 1:05 PM you must enter “1305”. This
parameter is only visible when the data logging option is installed.

9. Date (01/01/00-12/31/99)

This parameter sets the system date in month/day/year format. The complete date
must be entered without the digit separator “/” character, and with two digits for
each of the month, day and year. For example, to enter 5/2/94, you must enter
“050294”. This parameter is only visible when the data logging option is installed.