Technical data

Rated data

Operation with rated power (normal operation)

3

l

103

EDK82EV113 DE/EN/FR 11.0

Rated data

Operation with rated power (normal operation)

For data for operation at rated mains voltage and switching frequency 8 kHz, sin. data and restrictions
for other switching frequencys see system manual.

Type

Power

Rated mains voltage

Mains current [A]

Output current [A] )

Mass

[kW]

without

with

I

r

I

max

(60 s)

1)

[kg]

P

r

mains choke

E82xV302K2C

3.0

3/PE AC 230/240 V:

180 V −0 % ... 264 V +0 %
45 Hz −0 % ... 65 Hz +0 %

DC 325 V:

260 V −0 % ... 370 V +0 %

15.6

12.0

12.0

18.0

2.9

(E82CV... 2.4)

E82xV402K2C

4.0

21.3

16.0

16.5

24.8

E82xV552K2C

5.5

29.3

21.0

22.5

33.8

3.6

(E82CV... 3.0)

E82xV752K2C

2)

7.5

−

28.0

28.6

42.9

E82xV302K4C

3.0

3/PE AC 400 V:

320 V −0 % ... 440 V +0 %
45 Hz −0 % ... 65 Hz +0 %

DC 565 V:

450 V −0 % ... 620 V +0 %

9.0

7.0

7.3

11.0

2.9

(E82CV... 2.4)

E82xV402K4C

4.0

12.3

8.8

9.5

14.2

E82xV552K4C

5.5

16.8

12.0

13.0

19.5

3.6

(E82CV... 3.0)

E82xV752K4C

7.5

21.5

15.0

16.5

24.8

E82xV113K4C

2)

11

−

21.0

23.5

35.3

E82xV302K4C

3.0

3/PE AC 500 V:

400 V −0 % ... 550 V +0 %
45 Hz −0 % ... 65 Hz +0 %

DC 710 V:

565 V −0 % ... 775 V +0 %

7.2

5.6

5.8

11.0

2.9

(E82CV... 2.4)

E82xV402K4C

4.0

9.8

7.0

7.6

14.2

E82xV552K4C

5.5

13.4

9.6

10.4

19.5

3.6

(E82CV... 3.0)

E82xV752K4C

7.5

17.2

12.0

13.2

24.8

E82xV113K4C

2)

11

−

16.8

18.8

35.3

1)

Currents for periodic load change: 1 min overcurrent time with I

max

and 2 min base load time with 75 % I

r

2)

Operation only permitted with mains choke (

^

117)

Operation with increased rated power

,