Important codes for quick commissioning

7

l

148

EDK82EV113 DE/EN/FR 11.0

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C0002*

s

uSEr

(Cont.)

Transferring
parameter sets
with the keypad

Keypad

ð PAR1 (+ FPAR1)

Overwrite selected parameter set
and, if required FPAR1, with the
corresponding data of the keypad

71

with function module application I/O,
INTERBUS, PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen

11

with all other function modules

Keypad

ð PAR2 (+ FPAR1)

72

with function module application I/O,
INTERBUS, PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen

12

with all other function modules

Keypad

ð PAR3 (+ FPAR1)

73

with function module application I/O,
INTERBUS, PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen

13

with all other function modules

Keypad

ð PAR4 (+ FPAR1)

74

with function module application I/O,
INTERBUS, PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen

14

with all other function modules

Controller

ð keypad

Copy all available parameter sets
(PAR1 ... PAR4, if required FPAR1) into
the keypad

80

with function module application I/O,
INTERBUS, PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen

20

with all other function modules

Keypad

ð function module

Only overwrite the module−specific
parameter set FPAR1 with the data of
the keypad

40

only with function module INTERBUS,
PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen

Function module

ð keypad

Only copy the module−specific
parameter set FPAR1 into the keypad

50

only with function module INTERBUS,
PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen

C0002*

s

uSEr

(Cont.)

Saving your own
basic setting

9

PAR1

ð own basic setting

For the parameters of the controller
you can save an own basic setting
(e.g. the delivery status of your
machine):
1. Ensure that parameter set 1 is

active

2. Inhibit controller
3. Set C0003 = 3, confirm with

v

4. Set C0002 = 9, confirm with

v,

the own basic setting is saved

5. Set C0003 = 1, confirm with

v

6. Enable the controller