EDK82EV113 DE/EN/FR 11.0

Dismounting

8200vec612

1.

Disconnect the drive controller from mains and wait at least 3 minutes!

2.

To unlatch the circlip

4, position the screwdriver between the circlip and the function module

and press it to the right. Then remove the circlip

4.

3.

Grasp the bar of the plug connector

3 using tongs and unplug the plug connector together

with the function module

2.

4.

Fit the FIF cover

0 onto the FIF interface.