Parameter setting with E82ZBC keypad

,

Read the documentation for the keypad before starting work!

After every mains switching, or after connection of the keypad during operation, the 10 codes that
have been defined in code C0517 are immediately available.

By default, the user menu contains all codes required for commissioning a standard application with
linear V/f characteristic control:

Code

Designation

Lenze setting

C0050

Output frequency

Display: output frequency without slip compensation

C0034

Range of setpoint
selection

0

Standard I/O

X3/8: 0 ... 5 V / 0 ... 10 V / 0 ... 20 mA

Application I/O

X3/1U: 0 ... 5 V / 0 ... 10 V
X3/2U: 0 ... 5 V / 0 ... 10 V

C0007

Fixed configuration digital
inputs

0

E4

E3

E2

E1

CW/CCW

DCB

JOG2/3

JOG1/3

Clockwise

rotation/counter−clo

ckwise rotation

DC injection

brake

Selection fixed setpoints

C0010

Minimum output
frequency

0.00 Hz

C0011

Maximum output
frequency

50.00 Hz

C0012

Acceleration time main
setpoint

5.00 s

C0013

Deceleration time main
setpoint

5.00 s

C0015

V/f rated frequency

50.00 Hz

C0016

V

min

boost

device−dependent

C0002

Parameter set
management

Re−establish delivery status; transfer parameter sets by means
of the keypad; save, load, or copy own basic settings

)

Note!

Via C0002 "Parameter set transfer/establishing the delivery status", you can transfer
configurations from drive controller to drive controller by means of the keypad, or
re−establish the delivery status by loading the Lenze setting (e. g. if you’ve lost track
during parameterising).