Fault elimination, Drive errors, Troubleshooting and fault elimination – Lenze E82EV 8200 User Manual

Page 157

Advertising
background image

Troubleshooting and fault elimination

Fault elimination

Drive errors

8

l

157

EDK82EV113 DE/EN/FR 11.0

Fault elimination

Drive errors

Malfunction

Cause

Remedy

Motor does not rotate

DC−bus voltage too low
(red LED is blinking every 0.4 s;
keypad displays: LU)

Check mains voltage

Controller inhibited
(green LED is blinking, keypad displays:

c)

Deactivate controller inhibit,
controller inhibit can be set via
several sources

Automatic start inhibited (C0142 = 0 or 2)

LOW−HIGH edge at X3/28
If necessary, correct starting
condition (C0142)

DC−injection braking (DCB) active

Deactivate DC injection brake

Mechanical motor brake is not released

Manual or electrical release of
mechanical motor brake

Quick stop (QSP) active (keypad displays:

c) Deactivate quick stop

Setpoint = 0

Select setpoint

JOG setpoint activated and JOG frequency = 0 Select JOG setpoint

(C0037 ... C0039)

Active fault

Eliminate fault

Incorrect parameter set active

Change to correct parameter set via
terminal

Operating mode C0014 = −4−, −5− set, but no
motor parameter identification

Identify motor parameters (C0148)

Assignment of several functions excluding
each other to one signal source in C0410

Correct configuration in C0410

Use of internal voltage source X3/20 for the
function modules Standard I/O, INTERBUS,
PROFIBUS−DP, or LECOM−B (RS485):
No jumper between X3/7 and X3/39

Jumper terminals

Motor does not rotate smoothly

Motor cable defective

Check motor cable

Maximum current set too low (C0022,
C0023)

Adjust settings to the application

Motor is under− or overexcited

Check parameter setting (C0015,
C0016, C0014)

C0084, C0087, C0088, C0089, C0090, C0091
and/or C0092 not adjusted to the motor data

Adjust codes manually or identify
motor parameters (C0148);
optimise vector control

Current consumption of motor
too high

Setting of C0016 too high

Correct setting

Setting of C0015 too low

Correct setting

C0084, C0087, C0088, C0089, C0090, C0091
and/or C0092 not adjusted to the motor data

Adjust codes manually or identify
motor parameters (C0148);
optimise vector control

Advertising