Commissioning – Lenze E82EV 8200 User Manual

Page 149

Advertising
background image

Commissioning

Important codes for quick commissioning

7

l

149

EDK82EV113 DE/EN/FR 11.0

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C0002*

s

uSEr

(Cont.)

Loading/copyin
g the own basic
setting

By using this function you can also
just copy PAR1 into the parameter
sets PAR2 ... PAR4

5

own basic setting

ð PAR1

Restore own basic setting in the
parameter set selected

6

own basic setting

ð PAR2

7

own basic setting

ð PAR3

8

own basic setting

ð PAR4

C0003*

v

Saving
parameters
non−volatilely

1

0

Do not save parameters in the EEPROM

Data loss after mains switch−off

1

Always save parameters in the EEPROM

l

Active after every mains
connection

l

Cyclic alteration of parameters
via bus module is not permissible

3

Save your own basic setting in the
EEPROM

Afterwards save parameter set 1 as
own basic setting with C0002 = 9

C0007

v

uSEr

Fixed
configuration
digital inputs

Change of C0007 is copied into the
corresponding subcode of C0410.
Free configuration in C0410 sets
C0007 = 255!

0

E4

E3

E2

E1

l

CW/CCW = clockwise
rotation/counter−clockwise
rotation

l

DCB = DC injection brake

l

QSP = quickstop

l

PAR = change over parameter set
(PAR1

ó PAR2)

– PAR1 = LOW, PAR2 = HIGH
– The terminal in PAR1 and PAR2

has to be assigned with the
"PAR" function.

– Only use configurations with

"PAR" if C0988 = 0

l

TRIP−Set = external error

0

CW/CCW

DCB

JOG2/3

JOG1/3

1

CW/CCW

PAR

JOG2/3

JOG1/3

2

CW/CCW

QSP

JOG2/3

JOG1/3

3

CW/CCW

PAR

DCB

JOG1/3

4

CW/CCW

QSP

PAR

JOG1/3

5

CW/CCW

DCB

TRIP−Set

JOG1/3

6

CW/CCW

PAR

TRIP−Set

JOG1/3

7

CW/CCW

PAR

DCB

TRIP−Set

8

CW/CCW

QSP

PAR

TRIP−Set

9

CW/CCW

QSP

TRIP−Set

JOG1/3

10

CW/CCW

TRIP−Set

UP

DOWN

C0007

v

uSEr

(Cont.)

E4

E3

E2

E1

l

Selection of fixed
setpoints

JOG1/3 JOG2/3
LOW

LOW

HIGH

LOW

LOW

HIGH

HIGH

HIGH

Active
C0046
JOG1
JOG2
JOG3

11

CW/CCW

DCB

UP

DOWN

12

CW/CCW

PAR

UP

DOWN

13

CW/CCW

QSP

UP

DOWN

14

CCW/QSP

CW/QSP

DCB

JOG1/3

15

CCW/QSP

CW/QSP

PAR

JOG1/3

16

CCW/QSP

CW/QSP

JOG2/3

JOG1/3

17

CCW/QSP

CW/QSP

PAR

DCB

18

CCW/QSP

CW/QSP

PAR

TRIP−Set

19

CCW/QSP

CW/QSP

DCB

TRIP−Set

Advertising