Mechanical installation

Mounting with thermal separation (push−through technique)

4

l

107

EDK82EV113 DE/EN/FR 11.0

Cutout in the control cabinet

a1

a2

a3

b3

b3

b2

8200vec310

Dimensions [mm]

8200 vector

a1

a2

a3

b2

b3

E82DV302K2C
E82DV402K2C

80

+1

50

15

224

+1

23

E82DV552K2C
E82DV752K2C

123

+1

75

24

E82DV302K4C
E82DV402K4C

80

+1

50

15

E82DV552K4C
E82DV752K4C

123

+1

75

24

E82DV113K4C

Mounting
1.

Slide earthing clamps on the frame with the correct sides:
– The contact springs have to point towards the rear panel of the control cabinet.
– The cutouts of the seal specify the positions.

2.

Insert 8200 vector into cutout.

3.

Tighten by means of 4 screws M4x10.
– Tightening torque: 1.7 Nm (15 lb−in)