Wiring, Mains choke/mains filter assignment, Electrical installation – Lenze E82EV 8200 User Manual

Page 112

Advertising
background image

Electrical installation

Wiring
Mains choke/mains filter assignment

5

l

112

EDK82EV113 DE/EN/FR 11.0

Wiring

Mains choke/mains filter assignment

Operation with rated power at the 230V mains, 3/PE

8200 vector

Mains choke

Interference voltage category (EN 61800−3) and motor cable

length

Component

Component

Type

Var.

Type

C2

Max.

[m]

C1

Max.

[m]

E82xV302K2C

0xx

EZAELN3016B182

−

20

−

1)

2xx

E82ZZ40232B200

20

E82ZZ40232B200

20

E82ZZ40232B210

50

E82ZZ40232B210

50

E82xV402K2C

0xx

EZAELN3016B182

−

20

−

1)

2xx

E82ZZ40232B200

20

E82ZZ40232B200

20

E82ZZ40232B210

50

E82ZZ40232B210

50

E82xV552K2C

0xx

EZAELN3025B122

−

20

−

1)

2xx

E82ZZ75232B200

20

E82ZZ75232B200

20

E82ZZ75232B210

50

E82ZZ75232B210

50

E82xV752K2C

0xx

EZAELN3030B981

−

20

−

1)

2xx

E82ZZ75232B200

20

E82ZZ75232B200

20

E82ZZ75232B210

50

E82ZZ75232B210

50

1)

The motor cable length depends on the inverter type and the switching frequency

Advertising