Mounting and dismounting communication modules – Lenze E82EV 8200 User Manual
Page 133
![background image](/manuals/566001/133/background.png)
Extensions for automation
Modules
Mounting and dismounting communication modules
l
133
EDK82EV113 DE/EN/FR 11.0
Mounting and dismounting communication modules
)
Note!
Communication modules can be supplied by an internal or external voltage source. An
external voltage source is only required if communication to a node is to be maintained
in the case of a switch−off or if the node fails.
Mounting
8200vec616
1.
Set the type of voltage supply via the jumper
0.
– Position I: external voltage supply (delivery status; +24 V DC
±10%, max. 100 mA per
module)
– Position II: voltage supply via the internal voltage source
2.
Plug the communication module
1 to the AIF interface on the controller.
3.
If the communication module is provided with a safety screw
2, screw the module together
with the controller.