Electrical installation – Lenze E82EV 8200 User Manual
Page 122
Electrical installation
Mains connection
Fuses and cable cross−sections according to UL
l
122
EDK82EV113 DE/EN/FR 11.0
Operation at rated power
8200 vector
Rated fuse current / cable cross−section
Fuse
Circuit−breaker
Type
L1, L2, L3, N, PE
Type
L1, L2, L3, N, PE
Type
[A]
[AWG]
[A]
[AWG]
Mains 3/PE AC 230/240 V − operation without mains choke/mains filter
E82xV302K2C
20
12
−
−
E82xV402K2C
25
10
−
−
E82xV552K2C
30
8
4
)
−
−
E82xV752K2C
Operation only permitted with mains choke or mains filter
Mains 3/PE AC 230/240 V − operation with mains choke/mains filter
E82xV302K2C
20
12
−
−
E82xV402K2C
25
10
−
−
E82xV552K2C
35
−
−
−
E82xV752K2C
35
8
4
)
−
−
Mains 3/PE AC 400/500 V − operation without mains choke/mains filter
E82xV302K4C
15
14
−
−
E82xV402K4C
15
14
−
−
E82xV552K4C
20
12
−
−
E82xV752K4C
25
10
−
−
E82xV113K4C
Operation only permitted with mains choke or mains filter
Mains 3/PE AC 400/500 V − operation with mains choke/mains filter
E82xV302K4C
10
16
−
−
E82xV402K4C
15
14
−
−
E82xV552K4C
20
12
−
−
E82xV752K4C
25
10
−
−
E82xV113K4C
25
10
−
−
4)
Pin−end connector required