Commissioning, Selection of the correct operating mode – Lenze E82MV 8200 motec 0.55kW-2.2kW User Manual

Page 110

Advertising
background image

T

Commissioning

Selection of the correct operating mode

EDK82MV222 DE/EN/FR 9.0

L

NNM

léÉê~нбеЦ гзЗЙл кЙЕзггЙеЗЙЗ Сзк лн~еЗ~кЗ ~ййдбЕ~нбзел
qЬЙ СзддзпбеЦ н~ДдЙ ЬЙдйл узм нз СбеЗ нЬЙ ЕзккЙЕн зйЙк~нбеЦ гзЗЙ Сзк лн~еЗ~кЗ

~ййдбЕ~íáçåëW

Application

Operating mode

Single drives

Setting in C0014

recommended

alternatively

With extremely alternating loads

4

2

With high starting duty

4

2

With speed control (speed feedback)

2

4

With high dynamic response (e. g. positioning and infeed drives)

2

-

With torque setpoint

5

-

With torque limitation (power control)

2

4

Three-phase AC reluctance motors

2

-

Three-phase sliding rotor motors

2

-

Three phase motors with assigned frequency-voltage characteristic

2

-

Pump and fan drives with square-law load characteristic

3

2 or 4

Group drives
(several motors connected to one controller)
Identical motors and identical loads

2

-

Different motors and/or changing loads

2

-

`MMNQ Z OW дбеЙ~к sLС ЕЬ~к~ЕнЙкблнбЕ Езенкзд
`MMNQ Z PW ëèì~êÉJä~ï sLc ЕЬ~к~ЕнЙкблнбЕ Езенкзд
`MMNQ Z QW оЙЕнзк Езенкзд
`MMNQ Z RW лЙелзкдЙлл нзкимЙ Езенкзд