Commissioning, The most important codes for commissioning – Lenze E82MV 8200 motec 0.55kW-2.2kW User Manual

Page 129

Advertising
background image

Commissioning

The most important codes for commissioning

T

EDK82MV222 DE/EN/FR 9.0

NOV

L

Code

IMPORTANT

Possible settings

No.

Selection

Lenze

Name

C0148*

Motor

parameter

identification

0

0

Ready

Only when the motor is

cold!
1. Inhibit controller, wait until

drive is in standstill

2. Enter the correct motor

data under C0087, C0088,

C0089, C0090, C0091

(see motor nameplate).

3. Set C0148 = 1 by 
4. Enable controller

The identification
– starts,  goes off
– the motor makes a

high-pitched tone, but

does not rotate!

– takes approx. 30 s
– is completed when 

is on again

5. Inhibit controller

1

Start identification

z

V/f-rated frequency (C0015),

slip compensation (C0021) and

motor stator inductivity (C0092)

are calculated and saved.

z

The motor stator resistance

(C0084) = total resistance of

motor cable and motor is

measured and saved

C0517*

User menu

z

After mains switching or

when using the function
 the code from

C0517/1 will be displayed.

z

In Lenze setting, the user

menu contains the most

important codes for

starting-up the control

mode ”V/f characteristic

control with linear

characteristic”

z

When the password

protection is activated,

only the codes entered

under C0517 are freely

accessible.

z

Enter the required code

numbers in the subcodes.

Codes, which are only

active when being used

together with an

Application-I/O, cannot be

entered!

1 Memory 1

50

C0050 Output frequency (MCTRL1-NOUT)

2 Memory 2

34

C0034 Analog setpoint selection range

3 Memory 3

7

C0007 Fixed configuration - digital input

signals

4 Memory 4

10

C0010 Minimum output frequency

5 Memory 5

11

C0011 Maximum output frequency

6 Memory 6

12

C0012 Acceleration time main setpoint

7 Memory 7

13

C0013 Deceleration time main setpoint

8 Memory 8

15

C0015 V/f rated frequency

9 Memory 9

16

C0016 U

min

boost

10 Memory 10

2

C0002 Parameter set transfer

Advertising