T

Commissioning

The most important codes for commissioning

EDK82MV222 DE/EN/FR 9.0

L

NOM

Code

Possible settings

IMPORTANT

No.

Name

Lenze Selection

C0002*

uSEr

Parameter set

management

-11-

0

0

Ready

PAR1 ... PAR4:

z

Parameter sets of the

controller

z

PAR1 ... PAR4 also contain

parameters for

Standard-I/O,

Application-I/O,

AS interface or system

bus (CAN)

FPAR1:

z

Module-specific

parameter set of the

fieldbus function modules

INTERBUS, PROFIBUS-DP,

LECOM-B,

DeviceNet/CANopen

z

FPAR1 is saved in the

function module

Restorage of

default setting

1

Lenze setting

Ö

PAR1

Restorage of default setting

in the selected parameter set

2

Lenze setting

Ö

PAR2

3

Lenze setting

Ö

PAR3

4

Lenze setting

Ö

PAR4

31

Lenze setting

Ö

FPAR1

Restorage of default setting

in the fieldbus function

module

61

Lenze setting

Ö

PAR1 + FPAR1

Restorage of default setting

in the selected parameter set

of the controller and the

fieldbus function module

62

Lenze setting

Ö

PAR2 + FPAR1

63

Lenze setting

Ö

PAR3 + FPAR1

64

Lenze setting

Ö

PAR4 + FPAR1

C0002*

uSEr

(cont.)

Parameter set

transfer using

the keypad

Use the keypad to transfer

parameter sets to other

controllers.
During transfer the

parameters cannot be

accessed via other

channels!

Keypad

Ö

Controller

All available parameter sets

(PAR1 ... PAR4, and FPAR1)

are overwritten with the

corresponding keypad data

70

With function module

Application-I/O, INTERBUS,

PROFIBUS-DP, LECOM-B,

DeviceNet/CANopen

10

With all other function modules