Commissioning

The most important codes for commissioning

T

EDK82MV222 DE/EN/FR 9.0

NOR

L

Code

IMPORTANT

Possible settings

No.

Selection

Lenze

Name

C0007

uSEr

(cont.)

E4

E3

E2

E1

41

JOG1/3

DCB

TRIP set DFIN1-O

N

42

QSP

DCB

TRIP set DFIN1-O

N

43

CW/CC

W

QSP

TRIP set DFIN1-O

N

44

UP

DOWN

PAR

DFIN1-O

N

45

CW/CC

W

QSP

PAR

DFIN1-O

N

46

H/Re

PAR

QSP

JOG1/3

47

CW/QSP CCW/QS

P

H/Re

JOG1/3

48

PCTRL1

- OFF

DCB

PCTRL1

-I-OFF

DFIN1-O

N

49

PCTRL1

- OFF

JOG1/3

QSP

DFIN1-O

N

50

PCTRL1

- OFF

JOG1/3

PCTRL1

-I-OFF

DFIN1-O

N

51

DCB

PAR

PCTRL1

-I-OFF

DFIN1-O

N

255

Free configuration under C0410

Only display
Do not change C0007 since

settings under C0410 can be

lost

C0010

uSEr

Minimum

output

frequency

0.00 0.00

Æ

14.5 Hz

{0.02

Hz}

650.00

z

C0010 is not effective

with bipolar setpoint

selection (-10 V ... + 10 V)

z

C0010 only limits the

analog input 1

Æ

Speed setting range 1 : 6

for Lenze geared motors:

Setting absolutely required

for operation with Lenze

geared motors.

C0011

uSEr

Maximum

output

frequency

50.00 7.50

Æ

87 Hz

{0.02

Hz}

650.00

C0012

uSEr

Acceleration

time main

setpoint

5.00 0.00

{0.02

s}

1300.00 Reference: frequency change

0 Hz ... C0011

z

Additional setpoint

Ö

C0220

z

Acceleration times can be

activated via digital
signals

Ö

C0101