Commissioning, The most important codes for commissioning – Lenze E82MV 8200 motec 0.55kW-2.2kW User Manual

Page 121

Advertising
background image

Commissioning

The most important codes for commissioning

T

EDK82MV222 DE/EN/FR 9.0

NON

L

Code

IMPORTANT

Possible settings

No.

Selection

Lenze

Name

C0002*

uSEr

(cont.)

Parameter set

transfer using

the keypad

Keypad

Ö

PAR1 (+ FPAR1)

Overwrite selected parameter

set and, if necessary, FPAR1

with the corresponding

keypad data

71

With function module

Application-I/O, INTERBUS,

PROFIBUS-DP, LECOM-B,

DeviceNet/CANopen

11

With all other function modules
Keypad

Ö

PAR2 (+ FPAR1)

72

With function module

Application-I/O, INTERBUS,

PROFIBUS-DP, LECOM-B,

DeviceNet/CANopen

12

With all other function modules
Keypad

Ö

PAR3 (+ FPAR1)

73

With function module

Application-I/O, INTERBUS,

PROFIBUS-DP, LECOM-B,

DeviceNet/CANopen

13

With all other function modules
Keypad

Ö

PAR4 (+ FPAR1)

74

With function module

Application-I/O, INTERBUS,

PROFIBUS-DP, LECOM-B,

DeviceNet/CANopen

14

With all other function modules
Controller

Ö

Keypad

All available parameter sets

(PAR1 ... PAR4, and FPAR1)

are copied to the keypad

80

With function module

Application-I/O, INTERBUS,

PROFIBUS-DP, LECOM-B,

DeviceNet/CANopen

20

With all other function modules
Keypad

Ö

Function module

Overwrite the

module-specific parameter

set FPAR1 only

40

Only with function module

INTERBUS, PROFIBUS-DP,

LECOM-B, DeviceNet/CANopen
Function module

Ö

Keypad

Copy the module-specific

parameter set FPAR1 only

50

Only with function module

INTERBUS, PROFIBUS-DP,

LECOM-B, DeviceNet/CANopen

Advertising