Commissioning, Vector control – Lenze E82MV 8200 motec 0.55kW-2.2kW User Manual

Page 118

Advertising
background image

T

Commissioning

Vector control

EDK82MV222 DE/EN/FR 9.0

L

NNU

léíáãáëáåÖ нЬЙ оЙЕнзк Езенкзд
fе ЦЙеЙк~дI нЬЙ оЙЕнзк Езенкзд бл кЙ~Зу Сзк зйЙк~нбзе ~СнЙк нЬЙ гзнзк

й~к~гЙнЙкл Ь~оЙ ДЙЙе áÇÉåíáÑáÉÇK sÉÅíçê Езенкзд гмлн зеду ДЙ зйнбгблЙЗ Сзк

нЬЙ СзддзпбеЦ ЗкбоЙ йЙкСзкг~åÅÉW

JNMJ

Drive performance

Remedy

Rough motor run and motor current (C0054) > 60 %

rated motor current in idle running (stationary

operation)

1. Reduction of motor inductance (C0092) by 10 %
2. Check of motor current under C0054
3. If the motor current (C0054) > 50 % of the rated

motor current:
– C0092 must be reduced until the motor current

amounts to 50 % of the rated motor current

– Reduce C0092 by max. 20 %!
– Note: If you reduce C0092 the torque will

decrease!

Torque too low for frequencies f < 5 Hz (starting

torque)

Increase of motor resistance (C0084) or increase of

motor inductance (C0092)

Poor constant speed at high loads (setpoint and motor

speed are not proportional).

Increase of slip compensation (C0021)
Overcompensation results in drive instability!

Error messages OC1, OC3, OC4 or OC5 during

acceleration times (C0012) < 1 s (drive controller is no

longer able to follow the dynamic processes)

Change reset time of the I

max

controller (C0078):

z

Reduction of C0078 = I

max

controller becomes

quicker (more dynamic)

z

Increase of C0078 = I

max

controller becomes

slower (”smoother”)