U

Fault detection and elimination

Fault messages

EDK82MV222 DE/EN/FR 9.0

L

NPQ

c~мдн гЙлл~ЦЙл зе нЬЙ вЙуй~З зк бе нЬЙ й~к~гЙнЙк лЙннбеЦ йкзЦк~г

däçÄ~ä aêáîÉ `зенкзд

Keypad

PC

1)

Fault

Cause

Remedy

noer

0

No fault

-

-

ccr

71

System failure

Strong interference injections

on the control cables

Shield control cable

Earth loops in the wiring

ce0

61

Communication

error on AIF
(configurable in

C0126)

Faulty transmission of control

commands via AIF

Insert the communication module

properly into the diagnosis

terminal

ce1

62

Communication

error on CAN-IN1

with sync control

CAN-IN1 object receives faulty

data or communication is

interrupted

z

Check plug connection of bus
module

Ù

FIF

z

Check sender

z

Increase monitoring time in

C0357/1, if necessary

ce2

63

Communication

error on CAN-IN2

CAN-IN2 object receives faulty

data or communication is

interrupted

z

Check plug connection of bus
module

Ù

FIF

z

Check sender

z

Increase monitoring time in

C0357/2, if necessary

ce3

64

Communication

error on CAN-IN1

in case of event

or time control

CAN-IN1 object receives faulty

data or communication is

interrupted

z

Check plug connection of bus
module

Ù

FIF

z

Check sender

z

Increase monitoring time in

C0357/3, if necessary

ce4

65

BUS-OFF
(many

communication

errors occurred)

Controller has received to

many faulty telegrams via the

system bus and has been

disconnected from the bus

z

Check whether bus termination

is available

z

Check shielding of the cables

z

Check PE connection

z

Check bus load, reduce the

baud rate, if necessary

ce5

66

CAN time-out
(configurable in

C0126)

In case of remote

parameterisation via the

system bus (C0370):
Slave does not respond.

Communication monitoring

time has been exceeded

z

Check wiring of the system

bus

z

Check system bus

configuration

When operating with

Application I/O:
Parameter set change-over

has been parameterised

incorrectly

In all parameter sets, the ”change

over parameter set” signal

(C0410/13, C0410/14) must be

connected with the same source

When operating with module

on FIF:
Internal error

Contact Lenze