Commissioning

The most important codes for commissioning

T

EDK82MV222 DE/EN/FR 9.0

NOP

L

Code

IMPORTANT

Possible settings

No.

Selection

Lenze

Name

C0007

uSEr

Fixed

configuration

of digital

inputs

Change under C0007 will

be copied to the

corresponding subcode of

C0410. Free configuration

under C0410 sets C0007 =

255!

0

E4

E3

E2

E1

z

CW/CCW = CW

rotation/CCW rotation

z

DCB = DC-injection brake

z

QSP = Quick stop

z

PAR = Parameter set
changeover (PAR1

Ù

PAR2)
– PAR1 = LOW, PAR2 =

HIGH

– The terminal must be

assigned to the function

”PAR” in PAR1 and

PAR2.

– Configurations with

”PAR” are only allowed

if C0988 = 0

z

TRIP set = external fault

0

CW/CC

W

DCB

JOG2/3

JOG1/3

1

CW/CC

W

PAR

JOG2/3

JOG1/3

2

CW/CC

W

QSP

JOG2/3

JOG1/3

3

CW/CC

W

PAR

DCB

JOG1/3

4

CW/CC

W

QSP

PAR

JOG1/3

5

CW/CC

W

DCB

TRIP set

JOG1/3

j6

CW/CC

W

PAR

TRIP set

JOG1/3

7

CW/CC

W

PAR

DCB

TRIP set

8

CW/CC

W

QSP

PAR

TRIP set

9

CW/CC

W

QSP

TRIP set

JOG1/3

10

CW/CC

W

TRIP set

UP

DOWN

C0007

uSEr

(cont.)

E4

E3

E2

E1

z

Selection of

fixed

setpoints

JOG1/3 JOG2/3
LOW

LOW

HIGH

LOW

LOW

HIGH

HIGH

HIGH

active
C0046
JOG1
JOG2
JOG3

11

CW/CC

W

DCB

UP

DOWN

12

CW/CC

W

PAR

UP

DOWN

13

CW/CC

W

QSP

UP

DOWN

14

CCW/QS

P

CW/QSP

DCB

JOG1/3

15

CCW/QS

P

CW/QSP

PAR

JOG1/3

16

CCW/QS

P

CW/QSP

JOG2/3

JOG1/3

17

CCW/QS

P

CW/QSP

PAR

DCB

18

CCW/QS

P

CW/QSP

PAR

TRIP set

19

CCW/QS

P

CW/QSP

DCB

TRIP set