Rockwell Automation 1756-OF8I ControlLogix Eight-channel Isolated Analog I/O Modules  User Manual

Page 105

Advertising
background image

Rockwell Automation Publication 1756-UM540A-EN-P - May 2014

105

Install ControlLogix Isolated Analog I/O Modules

Chapter 6

WARNING:

This equipment shall be mounted in an ATEX-certified enclosure with a

minimum ingress protection rating of at least IP54 (as defined in IEC60529)
and used in an environment of not more than Pollution Degree 2 (as defined in
IEC 60664-1) when applied in Zone 2 environments. The enclosure must have a
tool-removable cover or door.

This equipment shall be used within its specified ratings defined by

Rockwell Automation.

Provision shall be made to prevent the rated voltage from being exceeded by

transient disturbances of more than 140% of the rated voltage when applied in
Zone 2 environments.

This equipment must be used only with ATEX certified Rockwell

Automation backplanes.

Secure any external connections that mate to this equipment by using screws,

sliding latches, threaded connectors, or other means provided with
this product.

Do not disconnect equipment unless power has been removed or the area is

known to be nonhazardous.

Advertising