Diagnostic Status Information

Publication 1770Ć6.5.16 - October 1996

Bytes

Description

Contents

Bits

3 - 4

all

Octal address of the start of the

PLC program

5 - 6

all

0 = not used

7 - 8

all

Starting byte address of diagnostic

counters and timers.

Starting byte address of diagnostic counters and timers.

9

0 - 4

Series and revision level of interface

module.

0 = Revision A

1 = Revision B, etc.

5 - 7

0 = Series A

1 = Series B, etc.

10

0 - 1

Settings of the option switches on the

0 = Undefined

1 = Undefined

g

p

node interface module

2 = Undefined

3 = not used

2

0 = PLCĆ2 processor

1 = All other PLCĆ2 Family processors

3

0 = Protected commands disabled

1 = Protected commands enabled

4

0 = Unprotected commands disabled

1 = Unprotected commands enabled

5

Not used

6

0 = Physical writes disabled

1 = Physical writes enabled

7

0 = Transmission unprotected commands disabled

1 = Transmission unprotected commands enabled

11

0

0 = No terminal directly connected

1 = Terminal directly connected

1

0 = No terminal is editing over DH+ link

1 = A terminal is editing over DH+ link

2

0 = Directly connected terminal is not editing

1 = Directly connected terminal is editing

3 - 7

Not used

will be set to zeros

12

0 - 2

Indicates the number of I/O racks the

3

PLCĆ2 is configured for.

0 = No I/O points are currently forced on or off.

1 = An I/O point has been forced on or off since the last

time the directly connected terminal was connected.

Important: This bit is set until the directly connected

terminal is disconnected or returns to the mode select"

screen, even if the forces have subsequently been

removed.