Diagnostic status, Disable forces, Disable outputs – Rockwell Automation 1770, D17706.5.16 Ref Mnl DF1 Protocol Command User Manual

Page 93

Advertising
background image

7–6

Communication Commands

Publication 1770Ć6.5.16 - October 1996

diagnostic status

Reads a block of status information from an interface module.
The reply contains the status information in its DATA field.
The status information varies with the type of interface module.
(For additional information, see Chapter 10, “Diagnostic Status
Information.”)

C

CMD

06

STS

FNC

03

TNS

R

CMD

46

STS

TNS

Data (max. 244 bytes)

DST SRC

SRC DST

disable forces

Disables the forcing function for I/O. All forcing data is ignored,
but remains intact.

CMD

0F

STS

FNC

41

TNS

C

CMD

4F STS

TNS

R

DST SRC

SRC DST

EXT

STS

disable outputs

Turns off all of the 1774-PLC processor’s outputs. Use this
command to disable the outputs before sending a physical write.

CMD

07

STS

FNC

00

TNS

C

CMD

47

STS

TNS

R

DST SRC

SRC DST

1774ĆPLC

MicroLogix 1000

PLCĆ2

PLCĆ3

PLCĆ5

PLCĆ5/250

(receive only)

SLC 500

SLC 5/03

SLC 5/04

MicroLogix 1000

PLCĆ5

PLCĆ5/250

(receive only)

SLC 500

SLC 5/03

SLC 5/04

1774ĆPLC