Rockwell Automation 1769-HSC Compact High Speed Counter Module User Manual

Page 118

Advertising
background image

118

Rockwell Automation Publication 1769-UM006E-EN-P - July 2013

Chapter 5 Diagnostics and Troubleshooting

X462

010

0 0110 0010

BadScalar_2

The Ctr2Scalar value is invalid, that is, less than one when
NumberofCounters = 10 or 11.

X463

010

0 0110 0011

BadScalar_3

The Ctr3Scalar value is invalid, that is, less than one when
NumberofCounters = 11.

X470

010

0 0111 0000

BadScale_0

The Ctr0CyclicRateUpdateTime is invalid, that is, less than one.

X471

010

0 0111 0001

BadScale_1

The Ctr1CyclicRateUpdateTime is invalid, that is, less than one
when NumberofCounters = 01, 10 or 11.

X472

010

0 0111 0010

BadScale_2

The Ctr2CyclicRateUpdateTime is invalid, that is, less than one
when NumberofCounters = 10 or 11.

X473

010

0 0111 0011

BadScale_3

The Ctr3CyclicRateUpdateTime is invalid, that is, less than one
when NumberofCounters = 11.

X480

010

0 1000 0000

BadRangeLimit_0

The Range0To11[0].LowLimit is greater than or equal to the
Range0To11[0].HighLimit.

X481

010

0 1000 0001

BadRangeLimit_1

The Range0To11[1].LowLimit is greater than or equal to the
Range0To11[1].HighLimit.

X482

010

0 1000 0010

BadRangeLimit_2

The Range0To11[2].LowLimit is greater than or equal to the
Range0To11[2].HighLimit.

X483

010

0 1000 0011

BadRangeLimit_3

The Range0To11[3].LowLimit is greater than or equal to the
Range0To11[3].HighLimit.

X484

010

0 1000 0100

BadRangeLimit_4

The Range0To11[4].LowLimit is greater than or equal to the
Range0To11[4].HighLimit.

X485

010

0 1000 0101

BadRangeLimit_5

The Range0To11[5].LowLimit is greater than or equal to the
Range0To11[5].HighLimit.

X486

010

0 1000 0110

BadRangeLimit_6

The Range0To11[6].LowLimit is greater than or equal to the
Range0To11[6].HighLimit.

X487

010

0 1000 0111

BadRangeLimit_7

The Range0To11[7].LowLimit is greater than or equal to the
Range0To11[7].HighLimit.

X488

010

0 1000 1000

BadRangeLimit_8

The Range0To11[8].LowLimit is greater than or equal to the
Range0To11[8].HighLimit.

X489

010

0 1000 1001

BadRangeLimit_9

The Range0To11[9].LowLimit is greater than or equal to the
Range0To11[9].HighLimit.

X48A

010

0 1000 1010

BadRangeLimit_10

The Range0To11[10].LowLimit is greater than or equal to the
Range0To11[10].HighLimit.

X48B

010

0 1000 1011

BadRangeLimit_11

The Range0To11[11].LowLimit is greater than or equal to the
Range0To11[11].HighLimit.

X490

010

0 1001 0000

BadCtrAssignToRange_0

This error occurs if you try to set Range0To11[0].ToThisCounter to
an invalid value (that is, to a counter that is not available due to
the number of counters selected).

X491

010

0 1001 0001

BadCtrAssignToRange_1

This error occurs if you try to set Range0To11[1].ToThisCounter to
an invalid value (that is, to a counter that is not available due to
the number of counters selected).

X492

010

0 1001 0010

BadCtrAssignToRange_2

This error occurs if you try to set Range0To11[2].ToThisCounter to
an invalid value (that is, to a counter that is not available due to
the number of counters selected).

Table 23 - Configuration Error Codes (Continued)

Hex
Equivalent

(1)

Module
Error
Code

Extended
Error
Information
Code

Error

Description

Binary

Binary

Advertising