Rockwell Automation 1769-HSC Compact High Speed Counter Module User Manual

Page 90

Advertising
background image

90

Rockwell Automation Publication 1769-UM006E-EN-P - July 2013

Chapter 4

Module Configuration, Output, and Input Data

14

Out
15

Out
14

Out
13

Out
12

Out
11

Out
10

Out
9

Out
8

Out
7

Out
6

Out
5

Out
4

Out
3

Out
2

Out
1

Out
0

Range Output Mask 0

15

Not used

RInv

Not used

LDW

Not used

RCntrNum

Range Configuration
Flags 0

16

RangeHighLimit_DWV_1

Range High Limit or
Direct Write Value 1

17

18

RangeLowLimit_1

Range Low Limit 1

19

20

Out
15

Out
14

Out
13

Out
12

Out
11

Out
10

Out
9

Out
8

Out
7

Out
6

Out
5

Out
4

Out
3

Out
2

Out
1

Out
0

Range Output Mask 1

21

Not used

RInv

Not used

LDW

Not used

RCntrNum

Range Configuration
Flags 1

22

RangeHighLimit_DWV_2

Range High Limit or
Direct Write Value 2

23

24

RangeLowLimit_2

Range Low Limit 2

25

26

Out
15

Out
14

Out
13

Out
12

Out
11

Out
10

Out
9

Out
8

Out
7

Out
6

Out
5

Out
4

Out
3

Out
2

Out
1

Out
0

Range Output Mask 2

27

Not used

RInv

Not used

LDW

Not used

RCntrNum

Range Configuration
Flags 2

28

RangeHighLimit_DWV_3

Range High Limit or
Direct Write Value 3

29

30

RangeLowLimit_3

Range Low Limit 3

31

32

Out
15

Out
14

Out
13

Out
12

Out
11

Out
10

Out
9

Out
8

Out
7

Out
6

Out
5

Out
4

Out
3

Out
2

Out
1

Out
0

Range Output Mask 3

33

Not used

RInv

Not used

LDW

Not used

RCntrNum

Range Configuration
Flags 3

Table 15 - Output Array - L23E Packaged Controller Enbedded HSC (Continued)

Word

Bit

Function

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00

Advertising