Rockwell Automation 1769-HSC Compact High Speed Counter Module User Manual

Page 84

Advertising
background image

84

Rockwell Automation Publication 1769-UM006E-EN-P - July 2013

Chapter 4

Module Configuration, Output, and Input Data

Range High Limit (Range0To11[n].HighLimit) and Range Low Limit
(Range0To11[n
].LowLimit)

IMPORTANT

The Range High Limit and Range Low Limit words do not apply to the
L23E packaged controller.

Configuration Array Words

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00

46 and 47

Range 0 High Limit

Range0To11[0].HighLimit

48 and 49

Range 0 Low Limit

Range0To11[0].LowLimit

52 and 53

Range 1 High Limit

Range0To11[1].HighLimit

54 and 55

Range 1 Low Limit

Range0To11[1].LowLimit

58and 59

Range 2 High Limit

Range0To11[2].HighLimit

60 and 61

Range 2 Low Limit

Range0To11[2].LowLimit

64 and 65

Range 3 High Limit

Range0To11[3].HighLimit

66 and 67

Range 3 Low Limit

Range0To11[3].LowLimit

70 and 71

Range 4 High Limit

Range0To11[4].HighLimit

72 and 73

Range 4 Low Limit

Range0To11[4].LowLimit

76 and 77

Range 5 High Limit

Range0To11[5].HighLimit

78 and 79

Range 5 Low Limit

Range0To11[5].LowLimit

82 and 83

Range 6 High Limit

Range0To11[6].HighLimit

84 and 85

Range 6 Low Limit

Range0To11[6].LowLimit

88 and 89

Range 7 High Limit

Range0To11[7].HighLimit

90 and 91

Range 7 Low Limit

Range0To11[7].LowLimit

94 and 95

Range 8 High Limit

Range0To11[8].HighLimit

96 and 97

Range 8 Low Limit

Range0To11[8].LowLimit

100 and 101

Range 9 High Limit

Range0To11[9].HighLimit

102 and 103

Range 9 Low Limit

Range0To11[9].LowLimit

106 and 107

Range 10 High Limit

Range0To11[10].HighLimit

108 and 109

Range 10 Low Limit

Range0To11[10].LowLimit

112 and 113

Range 11 High Limit

Range0To11[11].HighLimit

114 and 115

Range 11 Low Limit

Range0To11[11].LowLimit

Advertising