Range High Limit or Direct Write Value
(Range12To15[n
].HiLimOrDirWr)

This value can be used in one of two ways, depending on the setting of the Load
Direct Write (Range12To15[

n].LoadDirectWrite) bit.

When Load Direct Write = 0

When Range12To15[

n].LoadDirectWrite = 0, then

Range12To15[

n].HiLimOrDirWr is used in the range comparison (range

represents a count value or a rate value according to the programmed range type,
Range12To15[

n].Type).

When the range value is equal to Range12To15[

n].HiLimOrDirWr, Rangen will

change state. The range will become active or inactive depending on the
Range12To15[

n].Invert bit.

IMPORTANT

For the L23E packaged controllers embedded HSC, the ranges referred to
in this section are numbered 0…3 instead of 12…15. The ranges in this
section apply to only the 1769-HSC module and the CMX 5370 L2
packaged controllers embedded HSC.

Output Array Words

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00

10 and 11

Range 12 High Limit Direct Write Value

Range12To15[0].HiLimOrDirWr

16 and 17

Range 13 High Limit Direct Write Value

Range12To15[1].HiLimOrDirWr

22 and 23

Range 14 High Limit Direct Write Value

Range12To15[2].HiLimOrDirWr

28 and 29

Range 15 High Limit Direct Write Value

Range12To15[3].HiLimOrDirWr

TIP

Range12To15[n].HiLimOrDirWr must be higher than the
Range12To15[n].LowLimit or the InvalidRangeLimitn error flag in the
input array will be set.

TIP

Range12To15[n].HiLimOrDirWr can be higher than the maximum rate or
count value. For example, when the object value is a rate,
Range12To15[n].HiLimOrDirWr can be programmed in excess of
1,000,000 with no configuration error.

Range Value (Current Count or Current Rate)

Low Limit

High Limit or
Direct Write Value

INACTIVE

ACTIVE

INACTIVE

ACTIVE

ACTIVE

INACTIVE

Invert Bit = 0

Invert Bit = 1