Program a 1769-HSC Module, CompactLogix Controller, and 845F Incremental Encoder with RSLogix 5000 Software

Appendix B

6. Use this information to complete the Counter Configuration tab.

Your Counter Configuration tab should look like the example.

7. Click Apply.

8. Click the Output Configuration tab.

Option

Value

Maximum Count

1,200,000

Minimum Count

0

Preset

0

Hysteresis

0

Scalar

1

Update Time

1

Operation Mode

Choose an operation mode from the
pull-down menu, such as Pulse
Internal Direction.

Counter Reset Enable

This box displays for 1769-HSC/B
modules only.
The checkbox defaults with a check
mark if the selection bit is enabled
for this counter on the Add-On
profile.
Clear the checkbox to disable this
counter from resetting.
See

page 73

for more details.

Storage Mode

Nothing selected

Counter Mode

Ring Counter