background image

Appendix B

DTAM Plus Cable Diagrams

B–3

Catalog No. 2707-NC6

Use the ASCII Input cable to connect an ASCII device to the DTAM Plus
printer port. Use this cable with decoded bar code scanners.

RS-232C 9-Pin

2 = Data Out
3 = Data In
5 = Signal Ground

1

2

3

4

5

1

2

3

4

5

6

7

DTAM Plus RS-232C 9 Pin

2 = Data In
3 = Data Out
5 = Signal Ground

DTAM Plus RS-232C

Printer Port

RS-232 Synapse Interface

Cable

= Female Connector

= Male Connector

The communications port of the DTAM Plus must be set to RS-232.