Chapter 7
Troubleshooting and Maintenance

7–3

Message

Corrective Action(s)

Probable Cause(s)

Com Error Code: nnH
Press ENTER to Reset

Communication error code (nn)

Received a controller error code. Refer to next sec-
tion for error codes.

Attempt Was Made to ’Call’ An
Invalid Or Unprogrammed Screen

Illegal or unprogrammed screen type detected
(.CFG file error).

Check the program (.CFG) file and download.
Check screen links.

NAchip Set:Failed

Internal fault.

Contact Allen-Bradley for technical support.

Not Programmable

Master code is 99999999 and is not user-program-
mable.

A master code number of 99999999 may not be
changed from the keypad. Download a new, valid
master code number (using DPS Programming Soft-
ware).

Not Responding
Press ”Y” to Reset
”ENTER” To Continue

Communications fault.

Check cabling and retry.

Incorrect Master
Code

Master code entry did not match.

The master code entered did not match the master
code of the program file.

Invalid File Type
<Check CFG File>
Press ”Y” to Reset

Attempt was made to access an invalid file type.

Check application file. Refer to DPS user manual
for the file types that can be accessed.

Invalid Security
Code Access Denied

Master code or screen code did not match.

Either an incorrect master security code or a screen-
code that did not match the programmed screen
code was entered. Try again.

Loop Error
XX

The Communications Port test the transmitted char-
acter did not match the received character. The
transmitted character is displayed.

Verify that the loopback connector is connected to
the Communication and/or Printer Ports. If the loop-
back connectors are in place, possible damage to
the port drivers has occurred, send unit for repair.

** Input Error **
Press a Key to Cont.

The low and high data values are then dis-
played in one of two formats:

Low Lim High Lim
XXXXXX XXXXXX

Low XXXXXXX
High XXXXXXX

The data entered is not within the programmed lim-
its. The programmed Low and High limits are dis-
played.

Verify that the displayed limits are as programmed
for the entry field. Re-enter data within the entry
limits.

READ ONLY

The controller location is not configured for a Write
function (P-A/D function).

Verify that the controller location being accessed by
the P-A/D is acceptable for Write functions.

Prog SW/OI Version
Mismatch -OI Locked

An incorrect unlock code sent by DTAM Plus Pro-
gramming Software. Wrong version of DTAM Plus
Programming Software

Verify that the version of DTAM Plus Programming
Software is compatible for the controller type sup-
ported by the DTAM Plus.

Password Inhibited

Controller has at least one ladder program file that
is password protected.

Remove password protection.

Working
(Displayed for Long Period)

Comm port setting may be incorrect

DH-485 communication problems

Data entry screen has no data entry field

Check communication settings.

Verify connections and settings.

Reload corrected application file.