Troubleshooting and Maintenance

7–8

Use the keyboard test to verify that the keyboard is functioning properly.

To perform the keyboard test:

1. Use the [NEXT] or [PREV] keys to display Keyboard on the

test selection screen.

DTAM Plus Diagnostic
NEXT to Select Test
ENTER To Initiate

Keyboard

2. Press [

] to initiate the test.

The DTAM Plus prompts you to press each key in a sequential order.

Press ”MAIN MENU”

3. Press the keys as prompted form left to right beginning at the top.

Begin

End

You must press all of the keys in the order prompted. If you press the
wrong key, you must start over with the first key.

4. Pressing the last key in the sequence terminates the keyboard test.

The next test selection screen is displayed.

DTAM Plus Diagnostic
NEXT to Select Test
ENTER To Initiate

Comm Port

5. To terminate the test function , press the [NEXT] or [PREV] keys to

display Reset DUT in the test selection area. Press [

] to reset the

DTAM Plus.

Keyboard Test