Using the clear fault function – Rockwell Automation 2707-L40X_L8X_V40X DTAM Plus Operator Interface Module Installation Instructions User Manual

Page 137

Advertising
background image

Special Controller Functions

Appendix C

C–21

Use the Clear Fault function to clear all major and minor faults in the logic
controller.

To clear controller faults:

1. If you are clearing a PLC, the controller must be in Program or Remote

Program mode.

2. Select item 4 from the Special Menu to access the Clear Fault function.

You are prompted to clear faults:

Clear SLC Fault
Press ”Y”To Clear
All SLC 50X Faults
Press ”N” To Exit

Press ”Y”To Clear
All PLC 5 Faults
Press ”N” To Exit

SLC Controllers

PLC Controllers

3. Press [Y] to clear the faults or [N] to abort the function.

The faults are cleared and you are returned to the special functions menu:

Using the Clear Fault
Function