Chapter 5
Using the RS–232 Ports

5–39

Use this command to enable or disable discrete outputs or local Outputs I/O.
Use the following commands:

This command disables the outputs.

This command enables the outputs.

If the BCC is not valid, the Color CVIM module will respond with a DLE
NAK and the command will not be executed.

If the BCC is valid, the Color CVIM module will respond with a DLE ACK.
Then the Color CVIM module will validate the command structure. If the
command is valid, the Color CVIM module will execute the command. If the
command structure is invalid, the Color CVIM module will not execute the
command or respond.

Use the force command to turn the local I/O outputs either on or off. This
function can only be executed once per command. The only valid objects are
the fourteen discrete outputs. This command has the following structure:

Where the flags specify outputs 1 through 14:

Set individual Bits to select outputs 1 through
14

The data in this command indicates on or off (1 = ON and 0 = OFF).

Enable/Disable Outputs

Forcing Local I/O