Configuration blocks 37–39 – Rockwell Automation 5370 Color CVIM Communications Manual User Manual

Page 207

Advertising
background image

Appendix D
Configuration Data

D–8

Table D.6 shows the function of each word in the reference line 1–3
configuration blocks.

Table D.6
Configuration Blocks #37–39 – Reference Lines 1–3

Remote I/O

& RS–232

Word #

Bit #

Definition

Usage

Notes

0

0–15

Block Transfer Signature

1

0–7

Reserved

0 = Disabled

1

8

Enable

0 = Disabled
1 = Enabled

1

9–15

Reserved

2–7

0– 15

Reserved

8

0–7

X–Line High Threshold/
Gradient Threshold

0–197

8

8–15

Image number

0–37

9

0–7

Reserved

9

8–15

X–Line Low Threshold/Scale Factor

10

0–15

X–Line Head X Position

From upper left corner.

11

0–15

X–Line Head Y Position

From upper left corner.

12

0–15

X–Line Tail X Position

From upper left corner.

13

0–15

X–Line Tail Y Position

From upper left corner.

14

0–15

Reserved

Y–Line High Threshold/

15

0–7

Y–Line High Threshold/

0–197

15

0–7

Gradient Threshold

0–197

15

8–15

Image number

0–37

16

0–7

Reserved

16

8–15

Y–Line Low Threshold/
Scale Factor

17

0–15

Y–Line Head X Position

From upper left corner.

18

0–15

Y–Line Head Y Position

From upper left corner.

19

0–15

Y–Line Tail X Position

From upper left corner.

20

0–15

Y–Line Tail Y Position

From upper left corner.

21

0–15

Reserved

Configuration Blocks 37–39