Trigger operation command, Unlock command – Rockwell Automation 5370 Color CVIM Communications Manual User Manual

Page 124

Advertising
background image

Chapter 5
Using the RS–232 Ports

5–56

Use the trigger operation command to initiate an inspection. Use the
following commands:

09

Triggers an inspection

This function can only be executed once per command.

If the BCC is not valid, the Color CVIM module will respond with a DLE
NAK and the command will not be executed.

If the BCC is valid, the Color CVIM module will respond with a DLE ACK.
Then the Color CVIM module will validate the command structure. If the
command is valid, the Color CVIM module will execute the command and
return the data. If the command structure is invalid, the Color CVIM module
will not execute the command or respond.

Note: When using this command you should make sure that the Color CVIM
module is configured for a “hosted trigger source”.

Use the unlock command to enable the user interface (monitor and keyboard)
so that a user can access the SETUP. This command has the following
structure:

If the BCC is not valid, the Color CVIM module will respond with a DLE
NAK and the command will not be executed.

If the BCC is valid, the Color CVIM module will respond with a DLE ACK.
Then the Color CVIM module will validate the command structure. If the
command is valid, the Color CVIM module will execute the command. If the
command structure is invalid, the Color CVIM module will not execute the
command or respond.

Trigger Operation Command

Unlock Command