Appendix C
Numerical Results Data

C–16

If you request more results than will fit into 62 words, the Color CVIM will
truncate the data and set an error bit in word 1.

Note: Words 2 through 9 select tools in Remote I/O only (1771 node).

Note: The first byte in Results RS–232 DF1 is the command of 0D (hex)
preceded by the tool selection. The first three bytes in Statistics RS–232
DF1 are the command of 1600n (hex) where n is the statistic sample rate
preceded by the tool selection. Word 0, block signature and word 1 are not
used.

Use Table C.7 to set the contents of the programmable results block and
statistics block.

Table C.7
Programmable Results/Statistics Block Configuration

1771 Node Adapter

Results or Statistics

Function

RS–232 DF1

Results or Statistics

Word #

Bit #

Function

Byte #

Bit #

2

0

Module Status (NA for statistics)

0

0

2

1

Light Probe

0

1

2

2

Reference Line 1 (NA for statistics)

0

2

2

3

Reference Line 2 (NA for statistics)

0

3

2

4

Reference Line 3 (NA for statistics)

0

4

2

5

Reference Window 1

0

5

2

6

Reference Window 2

0

6

2

7

Reference Window 3

0

7

2

8

Window 1

1

0

2

9

Window 2

1

1

2

10

Window 3

1

2

2

11

Window 4

1

3

2

12

Window 5

1

4

2

13

Window 6

1

5

2

14

Window 7

1

6

2

15

Window 8

1

7

3

0

Window 9

2

0

3

1

Window 10

2

1

3

2

Window 11

2

2

3

3

Window 12

2

3

3

4

Window 13

2

4

3

5

Window 14

2

5

3

6

Window 15

2

6

3

7

Window 16

2

7

Results Block #6 (cont’d)